Control Current:<=30A
Packing List:1 Pc*Voltage Regulator
Size:show as pictures
Type: Voltage Regulator
Control Voltage:6-60V
Function description:
1. Automatic Charge control function
By setting the volt-HI:UP volt-LI:dn;When the battery voltage is below the volt-LI:dnthe relay leadsthe charger begins to charge the battery;when the battery voltage is up to volt-HI:UPthe relay is diconnected and the automatic charge is completed once;
2. Charge Time Control Function:
How to turn on the time control function?
After entering the parameter set set the parameter op is non-zero then turn on the time control function op default parameter is:--:--h the default does not turn on time control function;
After the opening Time control function (OP is non-zero) when the battery voltage is the lower volt-LIdn the charger began to charge the battery the system began to clock; During the timing the battery voltage volt-HIUP relay disconnect; If the OP time is up the battery voltage is still the lower volt-LIdn the relay keeps the conduction automatically closes the charge time control function and flashes the H:ER to remind the user the time parameter setting is unreasonable; Press any key to stop flashing;
Note: Time format: 00:59 (00 for hours 59 for minutes) The maximum time is 99:59 which is 100 hours.
3. Serial data upload and parameter setting function:
The system supports UART data upload and parameter setting
Parameter Setting:
Press and hold the SET key to enter the setting interface;
Switch the parameters you want to set by short press SET;
After the selection of parameters can be set by the UP/DOWN key to support the short press long press (fast increase or decrease); To set other parameters repeat step b c);
After all parameters are set long press set key to exit and save;
The Key Function Description:
In the Run interface (main interface):
Short press SET button to display the current set of parameters; Short press UP button toggle display charge percentage and charging time;
Short Press DOWN button select Turn on/off relay enabling if the relay can be closed will show off as a reminder;
Long press UP button switch low power state
OnNo operation in 10 minutes turn off backlight
OFF: Backlight is always bright
Long press SET buttonenter the parameter settings.
Calculation of voltage percentage
Voltage percentage = battery voltage/(volt-HI volt-LI)
Additional Features
A) Charging time recording function: not open charging time control the product will record a full time when the entry time display interface flashing display charging time and then exit time display interface or next charge to open (relay conduction) when empty;
B) Automatic parameter detection: When the parameters are set exit if volt-LI dn volt-HI UP the system will flash display ERR as a reminder;
C) Battery Access detection: This product attached to the battery if not connected to the battery the system will be shown in the downlink NbE as a reminder